Services




Kentledge, jack and dynamic-sensor photos are illustrative of typical pile load test set-ups, via Wikimedia Commons: U.S. Army / Pascal Demeuldre (public domain); Mississippi Department of Archives and History (no known restrictions); NCDOT Communications (CC BY 2.0).
A pile load test confirms, on site, how much load a pile can actually carry and how much it settles under that load. It replaces design assumptions with measured results before the structure is built on the piles.
BS Projects & Engineers Pvt. Ltd. plans, supervises and interprets static and dynamic pile load tests across West Bengal. Because our engineers also carry out soil investigation and foundation design, we read the test results against the design, not in isolation.
Developers, contractors, architects and industries in Kolkata, Howrah and North and South 24 Parganas engage us for static load tests on piles, both initial tests on trial piles and routine tests on working piles, as well as dynamic pile load tests, with a report that checks the results against the foundation design. We also carry out low strain pile integrity tests on working piles.
WhatsApp us | Call +91 98304 83074 | Request a Pile Load Test
The pile is loaded in stages with hydraulic jacks reacting against a kentledge (dead weight) or anchor piles, and settlement is measured with dial gauges at each stage. Tests are carried out as per IS 2911 (Part 4).
A drop weight strikes the pile head while sensors fixed to the pile record force and velocity. The signals are analysed to estimate the pile’s bearing capacity (high-strain dynamic testing, ASTM D4945). It needs no heavy kentledge, so several piles can be tested in less time.
A pile integrity test checks whether a cast-in-situ pile has defects along its length. A light hammer blow is applied to the pile head and a sensor records the reflected stress wave. The record shows changes in the pile section, such as necking, bulging, cracks or a discontinuity, and gives an estimate of the pile length.
Geotechnical investigation and soil testing · Structural and foundation design · Ground improvement · Non-destructive testing (NDT)
What is the difference between an initial and a routine pile load test?
An initial test is done on trial piles before construction to confirm the design capacity. A routine test is done on selected working piles during construction to check that they perform as designed.
How long does a pile load test take?
It depends on the test load, pile size and site access. We confirm the schedule after reviewing your pile design and site conditions.
Can a dynamic test replace a static pile load test?
A dynamic test can supplement, and on some projects partly replace, static tests. The choice depends on the project specification and the approving authority. We advise which method suits your project.
Does a pile integrity test give the pile capacity?
No. It finds defects and changes in the pile section and estimates the pile length. The load-carrying capacity is confirmed by a static or dynamic pile load test.
Can you also design the pile foundation?
Yes. Our engineers also carry out soil investigation and foundation design, so we read the pile load test results against the design.
Which areas do you cover for pile load tests?
We are based in Kolkata and carry out pile load tests in Kolkata, Howrah, North and South 24 Parganas and across West Bengal.
Call or WhatsApp +91 98304 83074 or email hello@bspepl.com with your pile layout, pile design and site location. We will suggest the right test and send a quotation.